Bathroom mirror remaining fogged up 20+ minutes after showering

Underpowered or clogged bathroom extractor fan failing to exhaust high-volume shower steam at the required 15 liters per second.

Severity
high
SafetyBathroom extractor electrical fans installed inside Zone 1 or Zone 2 must be IPX4 rated and fed via a residual current device (RCD/GFCI).

Symptoms

  • · Bathroom mirror and glazed tiles remain heavily fogged and dripping 20 minutes after shower ends
  • · Moisture runs down painted walls, creating yellowish water-streak staining
  • · Standard toilet paper square held against fan grille fails to stay attached by suction
  • · Extractor fan motor makes loud rattling, grinding, or humming noise without pulling air

What you should do

  1. 01Clean dust and lint mats clogging the extractor front grille, internal fan impeller blades, and backdraft shutter.
  2. 02Ensure the bathroom door has a minimum 10mm clearance undercut above threshold so replacement air can enter while fan exhausts.
  3. 03Adjust the fan overrun timer module to keep fan operating for at least 15-20 minutes after the bathroom light turns off.
  4. 04Replace weak 100mm axial fans on long duct runs with a high-pressure mixed-flow or centrifugal extractor delivering at least 20 L/s.
Recommended tool
Related guides

Airflow performance drops by 50% or more when connected to convoluted flexible accordion ducting exceeding 2 meters in length.